Product category
IoT Gateways: Wi-Fi / 4G RS485 MODBUS and Dixell Controller Gateways
An IoT gateway reads data from equipment that already has a digital interface, such as RS485 MODBUS sensors, refrigeration controllers and energy meters, and sends it to the cloud for dashboards, alerts and reports. It turns existing instruments into a MODBUS data logger without replacing them. Ideabytes IoT offers four gateways: Wi-Fi and 4G RS485 MODBUS gateways, a Wi-Fi dongle for Dixell controllers and an Android edge gateway with HDMI output, all reporting into the same platform as its data loggers.
4 models in this range
- GeM registered
- 21 CFR Part 11 reports
- Made in India
IoT gateways: 4 models
Every model logs to the Ideabytes cloud dashboard and produces audit-ready 21 CFR Part 11 reports.
Showing 4 products

IBI-CSC50R | Wi-Fi RS485 MODBUS Interfacing Gateway
8 Default Parameters (Configuration Charges additional)
- •Can Communicate up to 15 RS-485 MODBUS RTU enabled Devices
- •Maximum of 30 parameters can be monitored based on requirement (Single or Multiple RS485 Devices)

IBI-CSC50T | Wi-Fi Dixell Interfacing Gateway
Wi-Fi Dongle for Dixell Controller
- •Maximum of 20 parameters can be monitored based on requirement
- •Custom Reports (21CFR Part 11 Compliant) PDF, CSV, Excel

IBI-AGW | Edge Gateway - HDMI Out
Android Industrial IoT Gateway with HDMI Out (Configuration Charges additional)
- •Different Views (Dashboard / Map / List), Analytics, Device Management, User Management, Alerts Management
- •Remote Controlling

IBI-CSC50RM | 4G RS485 MODBUS Interfacing Gateway
8 Default Parameters (Configuration Charges additional)
- •Can Communicate up to 15 RS-485 MODBUS RTU enabled Devices
- •Maximum of 30 parameters can be monitored based on requirement (Single or Multiple RS485 Devices)
Compare models
| Model | Network | Connectivity | Mount Type |
|---|---|---|---|
| IBI-CSC50R | Wi-Fi | — | Wall/DIN Rail |
| IBI-CSC50T | — | — | — |
| IBI-AGW | — | Wi-Fi (802.11 b/g/n WiFi 6) | Bluetooth 4.2 | Ethernet: 1x 100M RJ-45 | Cellular 4G (Optional) | — |
| IBI-CSC50RM | 4G LTE CAT1 Technology with In-built M2M SIM | — | Wall/DIN Rail |
What an RS485 MODBUS gateway does
The IBI-CSC50R (Wi-Fi) and IBI-CSC50RM (4G LTE Cat 1 with a built-in M2M SIM) connect to an RS485 bus and poll MODBUS RTU devices such as refrigeration digital controllers, cold room controllers, pressure and PID controllers, water meters and energy meters. Each can communicate with up to 15 devices and monitor up to 30 parameters. Eight parameters are set up by default; further configuration is charged separately. Both mount on a wall or DIN rail and poll every 15 minutes by default.
In practice this makes the gateway an RS485 data logger for equipment you already own. A pharma plant can bring chamber controllers, compressor energy meters and RS485 temperature and humidity sensors onto one dashboard, and a food processor can log cold room set points alongside actual temperatures. Share the device models and register maps at enquiry so the parameters can be configured before dispatch.
Cold room controller monitoring without new sensors
Many cold rooms already have a controller with an accurate probe. Rather than drilling for a second sensor, a gateway reads the controller's own values and adds cloud logging, alarms and reports. The IBI-CSC50T is a Wi-Fi dongle for Dixell controllers: it communicates with up to 5 MODBUS RTU controller devices, monitors up to 20 parameters and stores up to 30 days of data if Wi-Fi or the internet fails. It adds maintenance schedules and ticket management, and exports reports as PDF, CSV or Excel.
Retrofitting this way keeps the controller as the single source of truth for temperature control, avoids a second set of probes that might disagree with it, and turns a cold room controller into a monitored, alarmed and reportable asset without a new sensor installation.
Edge gateway with HDMI for a local dashboard
The IBI-AGW is an Android industrial IoT gateway on a quad-core ARM processor (Rockchip RK3568) running Android 11 or Ubuntu 18.04. HDMI output up to 1920 x 1080 drives a control-room screen. It offers Wi-Fi, Bluetooth 4.2, 100M Ethernet and optional 4G, plus RS-232, RS-485, six digital inputs, two analogue inputs and one digital output. Configuration is charged separately.
It suits sites that want an on-premise view, such as a production floor display, a security desk screen or a location with limited internet, while still offering dashboard, map and list views, analytics, alerts management and remote control through the platform.
Which connectivity: Wi-Fi or 4G
Choose Wi-Fi (CSC50R or CSC50T) when the plant or cold store has reliable site Wi-Fi and IT is happy to add a device. Choose 4G (CSC50RM) for remote sites, rooftop plant or locations where the IT network is off limits: the built-in M2M SIM keeps the gateway independent. Use the AGW when the site needs Ethernet, a local screen or several interfaces.
Whichever gateway you choose, the MODBUS side is the same: a two-wire RS485 bus to the controllers, meters or sensors, each with its own address. If you are unsure whether a controller exposes MODBUS RTU, send its make and model and the team will check before you order.
21 CFR Part 11 reports from existing equipment
Gateway data flows into the same platform as the loggers: web and mobile apps, live alerts and push notifications, optional SMS, audit trail, alarm logs, trend graphs, MKT and 21 CFR Part 11 compliant PDF reports on demand or on a schedule. Features vary by plan, so confirm the report set with sales. For GMP and GDP sites this means cold rooms monitored through their controllers produce the same audit-ready evidence as rooms fitted with dedicated data loggers.
Used for
Frequently asked questions
What is a MODBUS data logger?
A MODBUS data logger reads values from devices on a MODBUS network, usually over RS485, and records them with a time stamp. The Ideabytes gateways do this and send the data to the cloud, so controllers, meters and RS485 sensors gain dashboards, alarms and audit-ready reports without new sensors.
How many devices can one gateway read?
The IBI-CSC50R and IBI-CSC50RM can communicate with up to 15 RS485 MODBUS RTU devices and monitor up to 30 parameters, with 8 parameters configured by default. The IBI-CSC50T Dixell dongle handles up to 5 controller devices and 20 parameters. Configuration beyond the defaults is charged separately.
Can I monitor my existing Dixell cold room controller over Wi-Fi?
Yes. The IBI-CSC50T is a Wi-Fi dongle for Dixell controllers. It reads the controller values, stores up to 30 days of data during an outage and sends everything to the cloud dashboard, with alerts and 21 CFR Part 11 compliant PDF, CSV or Excel reports.
How much does an IoT gateway cost?
It depends on the gateway, the number of devices and parameters to configure, Wi-Fi or 4G, and the software plan. Share your controller or meter models and the parameters you need through the contact form for a quote.
What is the HSN code for the gateways?
The IBI-CSC50R, CSC50RM and CSC50T gateways are listed under HSN 85176290 and the IBI-AGW edge gateway under HSN 84714900, as shown with each model number. Ideabytes is GeM registered for government purchases.
Related reading
Need help choosing the right logger?
Tell us what you store, how many points you need to monitor and which audits you face. Our team in Hyderabad will recommend a setup and send a quotation.