21 CFR Part 11

21 CFR Part 11 Compliant Data Loggers & Monitoring

A 21 CFR Part 11 compliance checklist is the list of controls a regulated company verifies before it relies on electronic records and electronic signatures instead of paper: unique user logins, secure audit trails, time-stamped data, signature controls, validation and record retention. For temperature and humidity monitoring it decides whether your data logger and its software will stand up to a US-FDA inspection. This page is for QA, validation and purchase teams at Indian pharma exporters, CROs and CDMOs. It gives a vendor checklist you can use in any evaluation and shows how Ideabytes IoT loggers, which produce 21 CFR Part 11 compliant PDF reports with audit trails and alarm logs, map against each point.

  • GeM registered
  • 21 CFR Part 11 reports
  • Made in India
Book an expert check
21 CFR Part 11 vendor checklist for a temperature monitoring system
RequirementWhat to look forHow Ideabytes addresses it
Unique user accountsEvery person has an individual login; no shared or generic accounts; users can be disabled without deleting history.The web platform includes user management, so each operator, reviewer and administrator gets an individual login.
Audit trailComputer-generated, time-stamped log of who changed what (limits, settings, users), which cannot be edited or switched off by users.An audit trail is part of the listed software features of the networked Wi-Fi, 4G and Ethernet loggers and the offline loggers.
Time-stamped recordsEvery reading carries date and time; no gaps when the network or power fails.Readings are logged at a configurable interval (15 minutes by default); single-channel loggers store 90 days on board and 8-channel units 40,000 records during outages.
Electronic signaturesSignature shows printed name, date, time and meaning (review, approval) and is permanently linked to the record.Tell us your review and approval workflow; we confirm how the platform supports it and share the details on request.
Data integrity and protected exportRaw data cannot be altered; exports and reports are generated by the system, not retyped.21 CFR Part 11 compliant PDF reports, with CSV and Excel export listed on customised systems; USB models create an encrypted PDF automatically.
Access controlsPermissions limited by role; only authorised users can change alarm limits or device settings.User, device and alert management sit in the platform; access levels are set up with your team at commissioning.
Validation documentationVendor documents that support your IQ, OQ and PQ, plus a clear description of the system.IQ/OQ support documents are available on request. Your PQ and user requirement specification stay with you.
Backup and retentionRecords kept and retrievable for the full retention period your SOP and the regulation require.Data is held on the cloud platform and buffered on the device; confirm the retention period for your plan when you order.
Alarm acknowledgement recordsWho saw each alarm, when, and what corrective action followed.Alarm logs and CAPA are listed platform features, alongside live alerts, app push notifications and optional SMS.
Report tamper-evidenceReports that cannot be edited without detection once issued.USB loggers such as the UT70 generate an encrypted PDF report on connection; the cloud issues Part 11 compliant PDF reports.

Who needs 21 CFR Part 11 compliance in India

Part 11 is a US regulation, but its reach in India is wide. Any site that makes, tests, stores or ships product for the US market and keeps GMP records electronically falls under it: formulation and API plants filing with US-FDA, contract research organisations generating study data, CDMOs manufacturing for US sponsors, and the warehouses and 3PLs that hold their stock. Temperature and humidity records are GMP records, so the monitoring system in a stability chamber, cold room or finished-goods warehouse is in scope as soon as those records are used to release a batch or defend it.

Domestic-only manufacturers now meet the same questions from export customers, from the auditors of multinational partners and, under Revised Schedule M, from Indian inspectors who expect computerised systems to be validated and their data protected.

21 CFR Part 11 requirements vs EU Annex 11 vs Schedule M

21 CFR Part 11 sets the conditions under which the US-FDA accepts electronic records (Subpart B) and electronic signatures (Subpart C): system validation, secure audit trails, limited access, operational checks and signature controls. FDA guidance allows a risk-based approach to some provisions, but audit trails and access control still feature heavily in inspection findings.

EU GMP Annex 11 covers computerised systems for the European market. It asks for many of the same record controls but puts more weight on the life cycle: supplier assessment, risk management, periodic review and business continuity. Revised Schedule M, India's GMP rule, expects validated computerised systems and reliable data without prescribing Part 11 mechanics. A monitoring system built for Part 11 usually covers the record controls of all three; the life-cycle items live in your SOPs.

21 CFR Part 11 audit trail requirements: what an inspector asks for

Inspectors rarely ask whether a system is Part 11 compliant. They ask to see evidence. Part 11 requires audit trails that are computer-generated, time-stamped, record the operator, never obscure earlier entries and are kept as long as the record itself. In a monitoring review, expect requests like these:

  • The current user list, showing who has access at what level, and proof that accounts are not shared
  • The audit trail for a sample period: alarm-limit edits, configuration changes and user additions, with who made them
  • Alarm and excursion records with acknowledgement, comments and the linked deviation or CAPA
  • The validation pack for the system and the calibration certificates for each probe
  • A report for a chosen date range, regenerated on the spot, that matches the archived copy
  • Evidence that data survived power cuts and network failures

Using the 21 CFR Part 11 compliance checklist in a vendor evaluation

The checklist above follows the order most validation teams work in: identity and access first, then the integrity of the data, then signatures, then evidence and retention. For each row, ask the vendor to demonstrate the control live rather than tick a questionnaire, and record the result in your supplier assessment.

Keep the split of responsibility clear. The vendor supplies a system capable of compliance and documents that support validation. You, the regulated user, own the user requirement specification, the risk assessment, performance qualification in your own facility, the SOPs for access, data review and backup, and periodic review. No data logger is compliant on its own out of the box; a validated system operated under approved SOPs is.

Part 11 compliant temperature monitoring system: how Ideabytes fits

Ideabytes IoT has built data loggers since 2009. Its networked loggers, on Wi-Fi, 4G M2M with a built-in SIM, or Ethernet, send readings to a cloud platform with web and mobile apps for iOS and Android. Listed software features include 21 CFR Part 11 compliant PDF reports, scheduled and on-demand reports, MKT values, audit trail, alarm logs, trend graphs, live alerts with app push notifications, optional SMS and CAPA records. Some software features are delivered in different plans, so confirm the plan at quotation.

On the hardware side, single-channel loggers store 90 days of readings at a 15-minute interval and the 8-channel PT100 units hold 40,000 records if the network drops, with internal Li-ion batteries to ride through power cuts. The USB logger UT70 produces an encrypted PDF report when plugged in, with no extra software. 44 of the 46 products in our catalogue list FDA 21 CFR Part 11, CE, FCC and IC in their compliance data.

Electronic records and electronic signatures in temperature monitoring

Electronic signatures are the row buyers most often skip. If QA signs off monthly temperature reports or excursion investigations electronically, each signature must show the printed name, date, time and meaning of the signature, be linked to the record so it cannot be copied to another, and belong to one unique user. If your process prints reports and signs them by hand, the signature controls apply less directly, but the electronic record behind the printout must still be protected and retained. Tell us which workflow you use and we will explain how the platform supports it.

Loggers with 21 CFR Part 11 support

Every listed model produces tamper-evident, audit-ready reports from the Ideabytes cloud.

Compare 4 models

Showing 7 products

IBI-MT350 | 4G M2M Temperature Data Logger
Temperature Data Logger

IBI-MT350 | 4G M2M Temperature Data Logger

Measuring Range from -200°C to +350°C

  • 4G LTE Cat1/2G fallback Connectivity
  • ± 0.5°C (-10°C to +50°C) Accuracy
IBI-WT350 | Wi-Fi Temperature Data Logger
Temperature Data Logger

IBI-WT350 | Wi-Fi Temperature Data Logger

Measuring Range from -200°C to +350°C

  • Wi-Fi 802.11 b/g/n 2.4 GHz Connectivity
  • ± 0.5°C (-10°C to +50°C) Accuracy
IBI-MTR8 | 4G M2M 8 Channel PT100 Temperature Data Logger (8 Temperature)
Temperature Data Logger

IBI-MTR8 | 4G M2M 8 Channel PT100 Temperature Data Logger (8 Temperature)

Measuring Range PT100 : -200°C to 550°C | PT1000 : -200°C to 550°C (Optional)

  • 4G LTE CAT1 Technology with In-built M2M SIM Connectivity
  • 0.5°C (0.05% of Full Scale) Accuracy
  • 2.4" 128X64 OLED monochrome Graphical Display
IBI-WTR8 | Wi-Fi 8 Channel PT100 Temperature Data Logger  (8 Temperature)
Temperature Data Logger

IBI-WTR8 | Wi-Fi 8 Channel PT100 Temperature Data Logger (8 Temperature)

Measuring Range PT100: -200°C to 550°C | PT1000: -200°C to 550°C (Optional)

  • Wi-Fi 802.11 b/g/n 2.4 GHz Connectivity
  • 0.5°C (0.05% of Full Scale) Accuracy
  • 2.4" 128X64 OLED monochrome Graphical Display
IBI-WTH120 | Wi-Fi Temperature & Humidity Data Logger
Temperature & Humidity Data Logger

IBI-WTH120 | Wi-Fi Temperature & Humidity Data Logger

Measuring Range from -40°C to +120°C | Humidity from 0% RH to 100% RH (Condensing)

  • Wi-Fi 802.11 b/g/n 2.4 GHz Connectivity
  • ± 0.5°C (-10°C to +50°C) Accuracy
IBI-MTH120 | 4G M2M Temperature & Humidity Data LoggerPopular
Temperature & Humidity Data Logger

IBI-MTH120 | 4G M2M Temperature & Humidity Data Logger

Measuring Range from -40°C to +120°C

  • 4G LTE CAT1 Technology with In-built M2M SIM Connectivity
  • ± 0.5°C (-10°C to +50°C) Accuracy
IBI-UT70 | USB Temperature Data Logger
Temperature Data Logger

IBI-UT70 | USB Temperature Data Logger

Measuring Range from -30°C to +70°C

  • Battery life up to 90 days
  • Software for configuration
  • Replaceable battery

Frequently asked questions

Is a data logger on its own 21 CFR Part 11 compliant?

No hardware is compliant on its own. Part 11 applies to the whole computerised system: logger, software, user controls, audit trail and the SOPs you operate it under. A vendor supplies a system capable of compliance, such as loggers that produce 21 CFR Part 11 compliant PDF reports with audit trails, and you validate it in your facility and control it with procedures.

What are the 21 CFR Part 11 audit trail requirements?

The audit trail must be computer-generated, secure and time-stamped. It records the date and time of operator entries and actions that create, modify or delete electronic records, must not obscure previously recorded information, and must be kept at least as long as the underlying records and be available for FDA review and copying.

What is the difference between 21 CFR Part 11 and EU Annex 11?

Part 11 is a US-FDA regulation focused on the controls for electronic records and electronic signatures. EU GMP Annex 11 is European guidance on computerised systems that covers similar record controls but adds more on the system life cycle: supplier assessment, risk management, periodic review and business continuity. Exporters serving both markets usually design SOPs that satisfy both.

Do you provide IQ/OQ validation documents?

IQ/OQ support documents are available on request for Ideabytes monitoring systems. They help your validation team qualify installation and operation. Performance qualification in your own storage areas, your user requirement specification and your SOPs remain the responsibility of your site. Share your validation template and we will align the documents to it.

How much does a Part 11 compliant temperature monitoring system cost?

It depends on the number of points and channels, the connectivity (Wi-Fi, 4G or Ethernet), the probe type and range, the software plan you need for reports and alerts, and whether calibration certificates and validation support are included. Request a quote with your room list and we will size the system for you.

Can we buy Part 11 ready loggers through GeM with calibration certificates?

Yes. Ideabytes IoT is registered on GeM, is a QCI-approved OEM and a DOT-approved M2M service provider for its SIM-based loggers. NABL-traceable calibration certificates are available on request, which most Indian tenders and pharma audits ask for alongside the datasheet and compliance statement.

What happens to the data if the Wi-Fi or mobile network fails?

The logger keeps recording. Single-channel Ideabytes loggers store 90 days of readings at a 15-minute interval and the 8-channel PT100 units store 40,000 records, then sync when the connection returns. Internal Li-ion batteries keep them running through power cuts, so there are no gaps in the record an inspector reviews.

Need audit-ready monitoring?

Tell us what you store, how many points you need to monitor and which audits you face. Our team in Hyderabad will recommend a setup and send a quotation.